| |  | EMC Data Domain DD620 |
|
| | • Deduplication storage for backup and archive at midsized data centers | | |
|
| | EMC Data Domain deduplication storage systems continue to revolutionize backup, archiving, and disaster recovery with high-speed, inline deduplication. |
| |
| Fast Inline Deduplication |
| Scalable Deduplication Storage |
| Data Invulnerability Architecture |
|
| |
| | | | | | | |
| TECHNICAL HIGHLIGHTS |
| Logical Capacity (Standard) |
83 TB (*)(***) |
| Logical Capacity (Redundant) |
415 TB (***)(*****) |
| Max. Throughput (Other) |
1.1 TB/hr (**) |
| Max. Throughput (DD Boost) |
2.4 TB/hr |
| Power Dissipation |
339 W (****) |
| Cooling Requirement |
1157 BTU/hr (****) |
| | |
| SOFTWARE |
| Software Features |
EMC Data Domain Operating System (DD OS) 5.2 or later: Global CompressionTM, Data Invulnerability Architecture including inline verification and integrated dual disk parity RAID 6, snapshots, telnet, FTP, SSH, email alerts, scheduled capacity reclamation, Ethernet failover and aggregation, Link Aggregation Control Protocol (LACP), VLAN tagging, IP aliasing.
Software Options for EMC Data Domain Deduplication Storage Systems are the following: - EMC Data Domain Boost: ADVANCED APPLICATION INTEGRATION, - EMC Data Domain Encryption: SECURE ENCRYPTION OF DATA-AT-REST, - EMC Data Domain Extended Retention: LONG-TERM RETENTION OF BACKUP DATA, - EMC Data Domain Replicator: NETWORK-EFFICIENT REPLICATION, - EMC Data Domain Retention Lock: SECURE DATA RETENTION FOR ARCHIVE DATA - EMC Data Domain Virtual Tape Library: INLINE DEDUPLICATION FOR SAN ENVIRONMENTS |
| Management |
EMC Data Domain Enterprise Manager (for single system management and reporting), EMC Data Domain Management Center (Centralized Management for Large Environments) , SNMP, and command line interface |
| Data Access |
NFS v3 over TCP, CIFS, DD Boost, tape library emulation (VTL) over Fibre Channel and NDMP Tape server. |
| | |
| SYSTEM EXPANSION |
| Internal Drives |
Seven or twelve 1 TB internal drives |
| Expansions |
No external expansion |
| | |
| PHYSICAL SPECIFICATIONS |
| Form factor |
2U 19-inch, rack mountable, use in 4-post rack, hotplug disks, redundant fans, redundant power supplies, serial port, 2 copper 10/100/1000. Ethernet ports, optional dual-port copper or optical 1 Gb Ethernet and quad-port copper 1 Gb Ethernet. |
| Size (HxWxD) |
2 EIA units (WxDxH: 48.3 cm x 55.9 cm x 8.9 cm) |
| Weight |
7 drives: 22.1 kg; 12 drives: 25.8 kg |
| | |
| POWER |
| Voltage |
100-120 / 200-240 V~ |
| Frequency |
50/60 Hz |
| Power consumption |
7 drives, 330 VA; 12 drives, 373 VA |
| Redundancy |
hotplug disks, redundant fans, redundant power supplies |
| | |
| ENVIRONNEMENTAL CONSTRAINTS |
| System Thermal Rating |
7 drives: 1061 BTU/hr, 311 Watts; 12 drives: 1157 BTU/hr, 339 Watts |
| Operating | | º Temperature |
10°C to 35°C, 35°C at 7500 feet, derate 1.1°C/1000 feet above 7500 feet to10,000 feet |
| º Relative humidity |
20% to 80% non-condensing |
| º Acoustic Noise |
Max 7.9 BA, sound power at 25°C |
| Non-operating | | º Temperature |
-40°C to +65°C |
| | |
| REGULATORY and SAFETY |
| Safety |
UL 60950-1, CSA 60950-1, EN 60950-1, IEC 60950-1, GS, SABS, GOST, IRAM |
| Emissions |
FCC Class A, EN 55022, CISPR 22, VCCI, BSMI, MIC, ICES-003 |
| Immunity |
EN 55024, CISPR 24 |
| Power Line Harmonics |
EN 61000-3-2 |
| | |
| WARRANTY |
| Standard warranty |
1-Y Hardware, 9x5, Next Business Day, parts only |
| Warranty extension |
Bull’s Global Care offer: Bronze, Silver and Gold levels; depends on location |
| | |
| NOTES |
| Note 1 |
*: Mix of typical enterprise backup data (filesystems, databases, e-mail, developer files), full backup weekly, incremental daily, to system capacity |
| Note 2 |
**: Maximum throughput achieved using VTL interface and 4 Gb/s Fibre Channel |
| Note 3 |
***:All capacity valeus are calculated using Base 10 |
| Note 4 |
****:Controller only |
| Note 5 |
*****: Mix of typical enterprise backup data (filesystems, databases, e-mail, developer files), full backup daily, to system capacity |
| |
|
| | |