| FORM FACTOR |
| Chassis |
Rack mount 7U drawer |
| Blade |
18 server blades per drawer |
| | |
| MANAGEMENT |
| Chassis Management Module |
x1 Chassis Management Module (CMM) including: |
| |
OPMA board with a microcontroller for drawer management |
| |
24-port 1Gb Ethernet switch / of which 3 external ports connected to the Ethernet switch |
| |
LED for status indications |
| Display Type |
Local Control Panel display on chassis front |
| | |
| COOLING |
| Fans per chassis |
x2 |
| Fans per blades |
x2 |
| | |
| INTERCONNECT |
| Infinband Switch Module (ISM) |
Module with 36 QDR ports (optional) |
| | |
| NETWORK |
| Ethernet Switch Module (ESM) |
1Gb for backbone access (optional) - TSM module: 10Gb Ethernet (optional) |
| | Passive board consisting of connectors for 18 server blades, 2 fan blades, ISM, UCM, CMM, ESM, PSUs |
| | |
| ULTRACAPACITOR |
| Ultra Capacitor Module (UCM) |
Ultra Capacitor Module to offset power outages up to 250ms (optional) |
| | |
| POWER SUPPLY |
| Power consumption (typical) |
5.5 KW |
| Power consumption (max) |
8.2 KW |
| Hot Swap PSU |
x4 hot-swap power blocks |
| Power Supply Redundancy |
N+1 redundancy on power |
| | |
| PHYSICAL SPECIFICATIONS |
| Size (HxWxD) |
31.1cm (7U) x 48cm (19”) x 74cm |
| Weight |
126 kg (full, maximum weight with all options) |
| | |
| REGULATORY & SAFETY |
| Safety |
CE (UL, FCC, RoHS) |
| |