| TECHNICAL HIGHLIGHTS |
| Form Factor |
Standard NEMA 19-inch rackmount. • 2 EIA units Single-Processor chassis, 12 drive slots • 3 EIA units Dual-Processor Chassis with SPS (includes optional second SPS), 12 drive slots • 2 EIA units SAS Disk Expansion Chassis with Dual Power Supplies, 12 drive slots |
| Storage Processor |
Single or Dual active/active |
| Host Connectivity |
• Fibre Channel models: 2 or 4 x 4 Gb/s FC ports per processor • iSCSI models: 2 x 1 Gb/s Ethernet ports per processor |
| Cache Memory |
1 GB per storage processor |
| Supported Protocols |
| º SAN |
Fibre Channel Protocol (FCP); iSCSI |
| LUNs |
512 Max. |
| Max. Hosts |
• Up to 10 HA hosts without Expansion Pack • Up to 64 HA hosts with Expansion Pack |
| Min/Max. Disk Drives |
• 4 to 12 without Expansion Pack • 4 to 60 with Expansion Pack |
| Max. Capacity (raw/formatted) |
116 TB (1) |
| Drives Supported |
| º SATA II 7200rpm |
750 GB(3), 1 TB and 2 TB 3.0 Gb/s |
| º SAS 10Krpm |
146(2), 300(2), 400(3) and 600 GB 3.0 Gb/s |
| º SAS 15Krpm |
146(3), 300, 450 and 600 GB 3.0 Gb/s |
| RAID Support |
RAID 1/0, 3, 5, 6 |
| Back-end Connectivity |
One 3 Gb/s SAS expansion port per processor |
| Reliability |
Redundant and hot-swappable controllers (if dual), drives, power/cooling modules, LCC cards |
| Availability |
• Multi-path management |
| |
• Mirrored cache, disk vault protected |
| |
• Preventive disk monitoring |
| |
• Global hot-spare disks |
| |
• Battery backup unit(s) on dual processor models |
| |
• Non-disruptive flare upgrade on dual processor models |
| | |
| HOST ENVIRONMENT |
| FC Host Support |
Windows, Linux, HP-UX, AIX, Solaris, VMware, NetWare (CLI and host utilities not included) (4) |
| iSCSI Host Support |
Windows, Linux, HP-UX, AIX, Solaris, VMware (4) |
| | |
| MANAGEMENT & ADMINISTRATION |
| Storage Management |
• Integrated Management Features: Navisphere Express Management, Shared Storage Control, Powerpath Path Multipathing, Snapshot Management, Non-disruptive Upgrade (dual SP only) • Navisphere Manager: management of optional software, management of multiple CLARiiON arrays, SSL Security, user authentication, automation via scripts |
| Multi-path Management |
PowerPath Multipathing bundled with Navisphere Express. Powerpath/VE option for Virtual Environment |
| Snap Shot |
Bundled with Navisphere Express, or SnapView™ |
| Performance Monitoring |
Navisphere Analyzer |
| Local Data Replication |
SnapView™ (Snapshots and Clones) (5) |
| Remote Data Replication |
MirrorView™ (5), SAN Copy™ (5) |
| Other |
ControlCenter 6.1 option, Replication Manager options, RepliStor option, VMware® Product Family |
| | |
| PHYSICAL SPECIFICATIONS |
| Dimensions (HxWxD) |
| º Disk Processor Enclosure |
Single-Processor Chassis: 3.5 in. (8.89 cm) 2 EIA units x 17.5 in. (44.45 cm) x 20 in (50.8 cm) Dual-processor Chassis with SPS: 5.25 in. (13.36 cm), 3 EIA units x 17.5 in. (44.45 cm) x 24 in. (60,96 cm) |
| º Disk Array Enclosure |
3.5 in. (8.98 cm) 2 EIA units x 17.5 in. (44.45 cm) x 20 in. (50.8 cm) |
| Weight |
| º Disk Processor Enclosure |
Single-SP: 57 lbs (26 kg) max.; Dual-SP with SPS (includes optional second SPS): 108 lbs (49.1 kg) max. |
| º Disk Array Enclosure |
54 lb (24.5 kg) max. |
| | |
| ENVIRONMENT |
| Temperature |
50-104 degrees F (10-40 degrees C) |
| Humidity |
20% to 80 % (non-condensing) |
| Altitude |
8,000 ft. (2438.4 m) @ 104 degrees F (40 degrees C) max.; 10,000 ft. (3048 m) @ 98.6 degrees F (37 degrees C) max. |
| | |
| POWER |
| Input Voltage |
100-240 VAC, single phase |
| Frequency |
47-63 Hz |
| Power consumption |
| º Disk Processor Enclosure |
490 VA (450 W) max. |
| º Disk Array Enclosure |
390 VA (360 W) max. |
| º Battery Backup Unit |
60 VA (40W) max. |
| Heat Dissipation |
| º Disk Processor Enclosure |
1,535 BTU/hr max. |
| º Disk Array Enclosure |
1,228 BTU/hr max. |
| º Battery Backup Unit |
21 BTU/hr |
| | |
| REGULATORY & SAFETY |
| Safety |
UL 60950-1, CSA C22.2-60950-1(ULC); EN 60950-1/IEC 60950-1; CNS; Manufactured under an ISO 9000-registered quality system |
| Electromagnetic Compatibility (EMC) |
FCC Class A, CE Mark, ICES-003 Class A (for Canada), EN55024 Immunity ITE, CISPR24 Immunity ITE, MIC/RRL Class A (for S Korea), EN55022 Class A, VCCI Class A (for Japan), AS/NZS 3548 Class A (For Autralia, New Zealand), BSMI Class A (for Taiwan), CISPR22 Class A |
| | |
| WARRANTY |
| Standard warranty |
World Wide; 3-year Hardware Support, 9x5, Next Business Day, parts only |
| Extended Warranty |
Bull’s Global Care offer: Bronze, Silver and Gold levels; depends on location |
| | |
| NOTES |
| Note 1 |
(1) The FLARE® storage operating environment requires 18 GB of disk space on each of the first four drives. |
| Note 2 |
(2) 2.5-inch drive within 3.5-inch carrier |
| Note 3 |
(3) SAS 146 GB 15 K, SAS 400 GB 10 K and SATA 750 GB 7.2 K disk drives are no longer commercialized. |
| Note 4 |
(4) Consult the EMC Interoperability Support Matrix |
| Note 5 |
(5) SnapView is supported on dual-controller FC or iSCSI front-end arrays. SAN Copy and MirrorView are supported on dual-controller FC front-end arrays. |
| |