| | |
| TECHNICAL HIGHLIGHTS |
| NAS Server |
Single or dual X-Blades, Dual X-Blade configurations can be deployed in primary/primary mode for the highest performance or primary/standby for for additional hardware availability protection (i.e. X-Blade failover). |
| Single X-Blade configuration |
| º Processor |
Dual 2.8GHz LV Intel Xeon Processors |
| º Memory |
4 GB Double Data Rate RAM (266MHz) |
| º Back-end Connectivity |
Two Fibre Channel ports for storage array connectivity |
| º Tape Connectivity |
Up to two Fibre Channel ports for tape connectivity |
| º Network Connectivity |
x4 10/100/1000 BaseT ports |
| º Optical Gigabit Ethernet port |
or two 10 Gigabit Ethernet optical ports and two 10/100/1000 BaseT ports |
| º Management Connectivity |
x1 10/100/100 port |
| Platform Management |
by a Control Station: |
| |
- Connection to each X-Blade via 10/100/1000 interface |
| |
- Manages X-Blade failover |
| |
- Manages all file systems via GUI |
| |
- SNMP MIB II manageability |
| |
- Secure Shell (SSH) for remote access |
| |
- HTTP server management interface |
| |
- Dual USB, 40 GB ATA, CD |
| Max. Capacity |
Up to 32 TB usable (16 TB max per active X-Blade) |
| Min/Max. Disk Drives |
4 to 60 SAS or SATA disks in up to four expansion enclosures |
| Drives Supported |
NX4 comes with integrated CLARiiON® AX4 storage featuring with the ability to mix both SAS and SATA disk types in the same enclosure. Interface capacity: 3.0 Gb/s SAS and SATA (RPM), SAS disks at 15,000rpm or 10,000rpm and SATA disks at 7,200rpm. |
| | |
| DART File Server Facilities |
| Protocols Supported |
| º File Systems |
NFSv2, v3, and v4, CIFS, FTP, FTP Secure, iSCSI, Fibre Channel |
| º NLM |
v1, v3, v4 |
| º RIP |
v1-v2 |
| º SNMP |
Yes |
| º NDMP |
v1-v4 |
| º ARP |
Yes |
| º ICMP |
Yes |
| º NTP |
client |
| º SNTP |
Yes |
| º Kerberos Authentication |
Yes |
| º LDAP |
Yes |
| DART Software Facilities |
| º Celerra Event Enabler |
Integration facilities with third-party vendors |
| º Celerra Replicator™ |
Replicate over IP for disaster recovery, backup, and/or testing |
| º Celerra Manager Advanced Edition |
Extended management and monitoring of multiple Celerra systems |
| º Celerra File-Level Retention |
Create WORM (write once/read many) file systems with a retention time |
| Client Connectivity Facilities |
| º File Access |
by FTP, FTP Secure, NFS, and CIFS |
| º Block Access |
by Fibre Channel and iSCSI |
| º Virtual Data Movers |
Microsoft® Windows® clients |
| º Ethernet Trunking |
Yes |
| º Link Aggregation |
IEEE 802.3ad |
| º Virtual LAN |
IEEE 802.1q |
| º UNIX Archive Utilities |
tar/cpio |
| º NSM |
v1 |
| º Port Mapper |
v2 |
| º NIS |
Client |
| º Microsoft DFS |
as Leaf node or Root Server |
| º NTLM |
NT LAN Manager |
| º LDAP Signing |
for Windows |
| º Microsoft Windows Server 2003 |
Native Windows 2000/2003/2008 support |
| º ABE |
Microsoft Windows Server® 2003 Access-based Enumeration (ABE) |
| CLARiiON Software Facilities |
PowerPath® is bundled |
| | |
| HIGH AVAILABILITY FEATURES |
| X-Blade Enclosure |
| |
- Redundant power supplies for X-Blades |
| |
- Hot-swappable power and cooling |
| |
- Internal environmental status monitoring |
| Control Station |
- X-Blade failover |
| |
- Auto-call events alerting |
| | |
| PHYSICAL SPECIFICATIONS |
| Dimensions (HxWxD) |
| º X-Blade Enclosure |
NX4 with 12 disks : 22.15x48.06x80.21 cm |
| º Expansion Disk Tray |
8.98x44.45x50.80 cm |
| Weight |
| º X-Blade Enclosure |
NX4 with 12 disks: 83.13 kg |
| º Expansion Disk Tray |
24.5 kg |
| | |
| ENVIRONMENT |
| Temperature |
10-40 °C |
| Temperature Gradient |
10 °C/hr |
| Humidity |
20% to 80% (non-condensing) |
| Altitude |
2,286.40 m @ 40 °C max, 3,048 m @ 37 °C max |
| | |
| PERFORMANCE |
| IOPS |
The estimated performance for each X-Blade is ~22.000 NFS Ops |
| | |
| AC POWER and DISSIPATION |
| Input Voltage |
100 to 240 VAC ±10%, single phase |
| Frequency |
47 to 63 Hz, full auto-ranging |
| Power consumption |
NX4 with 12 disks: 1,010 VA (960 W) max. Expansion Disk Tray: 390VA (360W) max. |
| Startup Surge Current |
59 A peak (1), at any line voltage |
| Power Factor |
0.98 minimum |
| Heat Dissipation |
NX4 with 12 disks: 3,275BTU/hr max. Expansion Disk Tray: 1,228BTU/hr max. |
| AC Inlet type |
IEC320-C14 appliance coupler |
| | |
| WARRANTY |
| Standard warranty |
World Wide; 3-year Hardware Support, 9x5, Next Business Day, parts only |
| Extended Warranty |
Bull’s Global Care offer: Bronze, Silver and Gold levels; depends on location |
| |