| TECHNICAL HIGHLIGHTS |
| VMAX Engine |
• Four quad-core 2.3 GHz Intel® XEON • Up to 128 GB of Memory |
| VMAX System |
• Up to 8 VMAX engines • Up to 1 TB of Memory |
| VMAX Interconnect |
Industry-standard RapidIO® fabric |
| Form Factor |
• System bay hosting system components. Storage bay hosting up to 240 drives |
| Host Connectivity |
4-128 4 or 8 Gb/s FC Host/SAN ports (4-16 per engine); 4-64 1 or 10 Gb/s iSCSI Host ports (4-8 per engine); 4-64 4 or 8 Gb/s FICON Host ports (4-8 per engine); 4-64 10 Gb/s FCoE Host ports (4-8 per engine) ¹ |
| Supported Protocols |
| º SAN |
Fibre Channel protocol (FCP), iSCSI, FICON, FCoE |
| º Other |
IPv6 with 1 Gb/s or 10 Gb/s Ethernet |
| Min/Max. Disk Drives |
48 - 2,400 |
| Max. Capacity (raw/formatted) |
Up to 2 PB of usable capacity |
| Drives Supported |
| º SAS 10Krpm |
2.5": 300, 450, 600 and 900 GB |
| º Fibre Channel 7200rpm |
3.5": 1, 2 and 3 TB |
| º Fibre Channel 10Krpm |
3.5": 300, 450 and 600 GB |
| º Fibre Channel 15Krpm |
3.5": 146, 300, 450 and 600 GB |
| º Flash Drives |
3.5": 100, 200 and 400 GB; 2.5": 200 GB |
| RAID Support |
| º RAID 1 |
Disk mirroring |
| º RAID 10 |
Distributed mirroring |
| º RAID 5 |
(3+1) and (7+1) striped data with rotating parity |
| º RAID 6 |
(6+2) and (14+2) striped data with dual rotating parity |
| Back-end Connectivity |
Up to 128 x 4 Gb/s (16 x 4 Gb/s per engine) |
| Reliability |
Redundant, hot-swappable components |
| Availability |
Multi-path access Mirrored cache, disk vault protected On-line upgrade Hot-spare Disks Battery back-up unit(s) |
| Storage Provisioning |
Symmetrix Virtual Provisioning; Auto-provisioning Groups |
| | |
| HOST ENVIRONMENT |
| FC Host Support |
Includes Linux, GCOS 7, GCOS 8, UNIX, Windows² |
| iSCSI Host Support |
Includes Linux, UNIX, Windows² |
| | |
| MANAGEMENT & ADMINISTRATION |
| Storage Management |
EMC Symmetrix Management Suite, EMC ControlCenter® ProSphere™ Suite, Unisphere |
| Multi-path Management |
PowerPath® for physical and virtual environments |
| Snap Shot |
TimeFinder® |
| Performance Monitoring |
Symmetrix Performance Analyser, FAST VP |
| Local Data Replication |
TimeFinder® , RecoverPoint |
| Remote Data Replication |
SRDF, RecoverPoint |
| Other |
Dynamic Cache Partitioning, Priority Control, Virtual LUN technology, WMware APIs for Array Integration (VAAI), VMware vSphere Storage APIs for Storage Avareness (VASA), Federated Live Migration, Replication Manager, Storage Configuration Advisor, Federated Tiered Storage, Data at Rest Encryption |
| | |
| PHYSICAL SPECIFICATIONS |
| Dimensions (HxWxD) |
• Front and Rear Service Area per bay: 42.0 in (106.7 cm) • An additional 18 in (45.7 cm) is required for ceiling/top clearance • Raised floor recommended |
| º System Bay |
76.66 in (194.7 cm) x 30.2 in (76.7 cm) x 41.88 in (106.4 cm) |
| º Storage Bay |
76.66 in (194.7 cm) x 30.2 in (76.7 cm) x 41.88 in (106.4 cm) |
| Weight |
| º System Bay |
4-engine: 1,830 lb (830 kg) max; 8-engine: 2,774 lb (1,258.3 kg) max |
| º Storage Bay |
2,144 lb (972.5 kg) max |
| | |
| ENVIRONMENT |
| Temperature |
50-90 degrees F (10-32 degrees C) |
| Humidity |
20%-80%, non-condensing |
| Altitude |
7,500 ft ( 2,286 m) max. |
| | |
| POWER |
| Input Voltage |
200-240 VAC • North America 3-phase (DELTA 4-WIRE); International 3-phase (WYE 5-WIRE); North America Single-phase; International Single-phase |
| Frequency |
50-60 Hz |
| Power consumption |
| º System Bay |
4-engine: 4.1 KVA max; 8-engine: 7.8 KVA max |
| º Storage Bay |
6.1 KVA max |
| Heat Dissipation |
| º System Bay |
4-engine: 13.7 KBTU/HR max; 8-engine: 26.3 KBTU/HR max |
| º Storage Bay |
19.8 KBTU/HR max |
| | |
| WARRANTY |
| Standard warranty |
3 year Hardware Support; 4 hour on site; 8-18 same business day |
| Extended Warranty |
3 year Hardware Support; Standard + 8 hour guaranteed repair time |
| | |
| NOTES |
| Note 1 |
¹ Combinations may be limited or restricted |
| Note 2 |
² Consult the EMC Interoperability Support Matrix |
| |