| TECHNICAL HIGHLIGHTS |
| VMAX Engine |
- 4 Quad-core 2.33 Ghz Intel® Xeon® processors - Up to 128 GB of Memory - Virtual Matrix bandwith: 24 GB/s |
| VMAX System |
One VMAX Engine |
| Form Factor |
System bay: 40 U cabinet hosting system components and up to 120 drives Storage bay: 40 U cabinet hosting up to 240 drives |
| Host Connectivity |
4-16 x 4 or 8 Gb/s FC ports; 4-8 x 1 or 10 Gb/s iSCSI ports; 4-8 x 4 or 8 Gb/s FICON ports ¹ |
| Remote Replication Connectivity |
2-4 x 4 or 8 Gb/s FC ports; 2-4 x 1 or 10 Gb/s GigE ports ¹ |
| Supported Protocols |
| º SAN |
Fibre Channel Protocol (FCP); iSCSI; FICON |
| º Other |
IPv6, IPsec and compression available with GigE ports |
| Min/Max. Disk Drives |
48-360 |
| Drives Supported |
| º SATA II 7200rpm |
1 TB, 2 TB and 3 TB 4 Gb/s FC |
| º SAS 10Krpm |
300, 450 and 600 GB 4 Gb/s FC |
| º Fibre Channel 10Krpm |
300, 400, 450 and 600 GB 4 Gb/s |
| º Fibre Channel 15Krpm |
146, 300, 450 and 600 GB 4 Gb/s |
| º Flash Drives |
100, 200 and 400 GB 4 Gb/s FC |
| RAID Support |
RAID 0, 1, 10, 5, 6 |
| º RAID 0 |
No data protection, striped data |
| º RAID 1 |
Disk mirroring |
| º RAID 10 |
Data striped across mirrored pairs |
| º RAID 5 |
RAID 5 (3+1) and RAID 5 (7+1); striped data with rotating parity |
| º RAID 6 |
RAID 6 (6+2) and RAID 6 (14+2); striped data with dual rotating parity |
| Back-end Connectivity |
16 x 4 Gb/s |
| Management |
EMC Ionix™ ControlCenter® software suite, EMC Symmetrix Management Console |
| Reliability |
Redundant, hot-swappable components |
| Availability |
Multi-path access |
| |
Mirrored cache, disk vault protected |
| |
On-line upgrade |
| |
Hot-spares disks |
| |
Battery back-up unit(s) |
| Storage Provisioning |
Symmetrix Virtual Provisoning, Auto-provisioning Groups |
| | |
| HOST ENVIRONMENT |
| FC Host Support |
Includes UNIX, Linux, Windows, GCOS 7, GCOS 8, z/OS ² |
| iSCSI Host Support |
Includes UNIX, Linux, Windows ² |
| | |
| MANAGEMENT & ADMINISTRATION |
| Storage Management |
EMC Ionix™ ControlCenter® software suite, EMC Symmetrix Management Console, FAST VP |
| Multi-path Management |
PowerPath® for physical and virtual environnements |
| Snap Shot |
TimeFinder® software family |
| Performance Monitoring |
Symmetrix Performance Analyser, ControlCenter® Symmetrix Optimizer |
| Local Data Replication |
TimeFinder® software family, RecoverPoint |
| Remote Data Replication |
Symmetrix Remote Data Facilities (SRDF®) software family, RecoverPoint |
| Other |
Dynamic Cache Partitioning, Priority Control, Virtual LUN Technology, Data At Rest Encryption, VMware APIs for Array Integration (VAAI), VMware vSphere Storage APIs for Storage Awareness (VASA), Federated Live Migration |
| | |
| PHYSICAL SPECIFICATIONS |
| Dimensions (HxWxD) |
- Front and Rear Service Area per bay: 42.0 in (106.7 cm) - An additional 18 in (45.7 cm) is required for ceiling/top clearance - Raised floor recommended |
| º System Bay |
76.66 in (194.7 cm) x 24.0 in (61.0 cm) x 41.88 in (106.4 cm) |
| º Storage Bay |
76.66 in (194.7 cm) x 30.02 in (76.7 cm) x 41.88 in (106.4 cm) |
| Weight |
| º System Bay |
1,730 lb (784.7 kg) max. |
| º Storage Bay |
2,144 lb (972.5 kg) max. |
| | |
| ENVIRONMENT |
| Temperature |
50-90 degrees F (10-32 degrees C) |
| Humidity |
20% to 80%, non-condensing |
| Altitude |
7,500 ft (2,286 m) max. |
| | |
| POWER |
| Input Voltage |
System Bay: North America 3-phase (Delta-4 wire) / International 3-phase (Wye-5 wire) / Single phase: 200-240 VAC Storage Bay: North America 3-phase (Delta-4 wire) / International 3-phase (Wye-5 wire) / Single phase: 200-240 VAC |
| Frequency |
50 - 60 Hz |
| Power consumption |
| º System Bay |
4.3 kVA max |
| º Storage Bay |
6.1 kVA max. |
| Heat Dissipation |
| º System Bay |
14,200 BTU/hr max. |
| º Storage Bay |
19,800 BTU/hr max. |
| | |
| WARRANTY |
| Standard warranty |
3 year Hardware Support; 4 hour on site, 9-18 same business day |
| Extended Warranty |
3 year Hardware Support; Standard + 8 hour guaranteed repair time |
| | |
| NOTES |
| Note 1 |
¹ Combinations may be limited or restricted |
| Note 2 |
² Consult the EMC Interoperability Support Matrix |
| |