| FILE COMPONENTS |
| # File X-Blades |
1 or 2 |
| # Control Stations |
1 or 2 |
| X-Blade: CPU/Memory |
The latest 64 bit Intel Xeon 5600 Processor (6-core 2.83 GHz CPUs with 12 MB of Layer 3 cache) / 24 GB Double Data Rate 3 RAM (1333 MHz)
|
| Max File Flex IO Modules per X-Blade |
3 |
| Max Ports per X-Blade |
| º Min/Max 2/4/8 Gb/s FC |
Up to two Fibre Channel ports for tape connectivity; Two Fibre Channel or Fibre Channel over Ethernet (FCoE) ports for storage connectivity |
| º Max IP |
4 |
| º Max 1 GBaseT |
4 |
| º 10 GbE iSCSI Min/Max |
0/2 |
| | |
| VNX CONNECTIVITY |
| Management |
One 10/100/1000 management port |
| | The VG2 connects via Fibre Channel or FCoE SAN to: EMC Symmetrix storage systems; EMC VNX™ series storage platforms; EMC CLARiiON® storage system. A single X-Blade configuration can be upgraded non-disruptively to a dual X-Blade configuration.
Client connectivity facilities; File can be accessed by FTP, NFS (including pNFS), CIFS, and MPFS; Block access by native array connectivity (iSCSI and FC); Virtual Data Movers for Microsoft® Windows® clients; Ethernet Trunking; Link aggregation (IEEE 802.3ad); Virtual LAN (IEEE 802.1q); UNIX archive utilities (tar/cpio); Network Status Monitor (NSM) v1; Portmapper v2; Network Information Service (NIS) client; Supports Microsoft DFS as Leaf node or Root Server; Native Windows 2000/2003/2008 support; NT LAN Manager (NTLM); LDAP signing for Windows; Microsoft Windows Server 2003 Access-based Enumeration (ABE)
|
| | |
| VNX SOFTWARE |
| Management Software |
Instance of VNX Operating Environment for File software |
| Supported Protocols |
NFS, CIFS, FTP, FTP Secure (FTP over SSL), and IPv6; Network Lock Manager (NLM); Common Criteria Certification: EAL 3+ Assurance Level; Routing Information Protocol (RIP); Simple Network Management Protocol (SNNP); Network Data Management Protocol (NDMP); Address Resolution Protocol (ARP); Internet Control Message Protocol (ICMP); Network Time Protocol (NTP) client; Simple Network Time Protocol (SNTP); Kerberos Authentication; Lightweight Directory Access Protocol (LDAP) |
| Software Suites |
EMC Unisphere: provides a simple consolidated interface to manage both VNX, CLARiiON and EMC Celerra platforms; VNX Event Enabler (VEE): integration facilities with third-party vendors: Anti-virus: VNX integration with industry-leading, anti-virus vendors, Event Publishing VNX integration with industry-leading, quota-management, and auditing vendors; EMC VNX Replicator™: replicate over IP for disaster recovery, backup, and/or testing, VNX File-Level Retention (FLR): create WORM (write once/read many) file systems with specified retention periods; supports both an Enterprise and Compliance option VNX Multi-Path File System (MPFS): delivers improved performance and scalability over traditional NAS; Note: Virtual Provisioning™, Deduplication, and EMC SnapSure™ licenses are bundled.
|
| Optional Wmware Facilities |
VNX Plug-in for VMware: for provisioning, management, cloning and deduplication; EMC PowerPath®/VE: path management for iSCSI and Fibre Channel; Site Recovery Manager (SRM): managing failover and failback making disaster recovery rapid and reliable; Replication Manager: host-based management of array-based copies of data |
| Additionnal Options |
PowerPath: path management; Replication Manager: host-based management of array-based copies of data; Cloud Tiering Appliance: transparent file-based tiering within and across platforms |
| | |
| PHYSICAL SPECIFICATIONS |
| Form factor |
| º Processor Enclosure |
2 U |
| º Control Station |
1 U |
| Size (HxWxD) |
7 in. (17.78 cm) x 18.92 in. (48.06 cm) x 31.58 in. (80.21 cm) |
| Weight |
73.8 lb (33.48 kg): one blade enclosure, two Control |
| | |
| ENVIRONMENT |
| Temperature |
50–104 degrees F (10–40 degrees C) |
| Temperature Gradient |
18 degrees F/hr (10 degrees C/hr) |
| Humidity |
20 percent to 80 percent (non-condensing) |
| Altitude |
7,500 ft (2286 m) @ 104° F (40° C) max. |
| | |
| POWER |
| Input Voltage |
100 to 240 V AC, single-phase |
| Frequency |
50-60 Hz, |
| Power consumption |
VG2 with 2 X-Blades and one control station : 590 VA (510 W) maximum |
| Heat Dissipation |
VG2 with 2 X-Blades and one control station: 1.84 x 106 J/hr, (1,700 Btu/hr) maximum |
| | |
| WARRANTY |
| Standard warranty |
World Wide; 3 years Hardware Support, 9x5, Next Business Day, parts only |
| Extended Warranty |
Bull’s GlobalCare offer: Bronze, Silver, Gold levels; depends on location |
| |