| GLOBAL CHARACTERISTICS |
| Rack chassis version |
2U base with disks + 2U disks drawers; 12x3.5’’ slots drawer or 24x2.5’’ slots drawer; maximum 96 disks |
| Total Storage Capacity |
Up to 86.4 TB SAS or 288 TB NL-SAS |
| Disk modules (hot swap) |
3 to 96 disks (12x3.5’’ or 24x2.5’’ per drawer) |
| RAID capability |
RAID0, 1, 5, 6, 10, 50 and Triple Mirror |
| Interface to host |
8 Gb/s Fibre Channel or 1 Gb/s iSCSI or 10Gb/s iSCSI or 6Gb/s SAS |
| Max number of port to host |
Mono : 2 or 4 FC, 2x iSCSCI 1Gb/s or 10Gb/s, 2x SAS 6Gb/s Dual : 4 or 8 FC, 4x iSCSCI 1Gb/s or 10Gb/s, 4x SAS 6Gb/s |
| Interface to disks |
2x 6Gb/s SAS links |
| Power Supply Redundancy |
Yes |
| Fan Redundancy |
Yes |
| | |
| CONTENT OF BASIC CHASSIS |
| RAID controller /SP |
Single or dual controller FC or iSCSI 1Gb/s or iSCSI 10Gb/s or SAS 6Gb/s |
| Cache memory per RAID controller/SP |
4 GB (8GB in dual controller) |
| Cache memory configurability |
Yes |
| Hot-Plug Power Supply |
Yes |
| Battery Backup (BBU ou SPS) |
BBU for copy of cache in flash on the controller in case of power down |
| Host Management |
LAN TCP/IP, FC SES, snmp, email events |
| | |
| OPTIONS ON TOP OF BASIC CHASSIS |
| Additional RAID controller /SP |
Mono to dual controller upgrade, with same type of controller |
| Hard Disk Drives 7.2Krpm |
2,5’’ : 3 x 1000 GB ; 3,5’’ : 3 x 1000 GB , 3x 2000GB, 3x 3000GB |
| Hard Disk Drives 10Krpm |
2,5’’ : 3 x 300 GB SAS, 3 x 450 GB, 3x 600GB, 3x 900GB |
| Hard Disk Drives 15 Krpm |
3,5’’ : 3 x 300 GB SAS, 3 x 450 GB, 3x 600GB |
| Solid State Drives |
2,5’’ : 1x 100GB, 1x 400GB; 3,5’’ : 1x 100GB, 1x 400GB |
| | |
| STORAGE MANAGEMENT SOFTWARE |
| Storage Management |
StoreWay Optima Manager (included with hardware) |
| Multi-path Management |
StoreWay Multipath for Windows and Linux (included with hardware); StoreWay Multipath for VMware (free option); StoreWay Multipath for AIX (free option) |
| LUN mapping/Multi-server storage access |
Yes |
| Performance Monitoring |
Performance Monitor, Performance Navigator, Performance Monitor Suite (options) |
| Snap Shot |
Dynamic snap volume (option included with Local Data Replication) |
| Local Data Replication |
Local data replication (option) |
| Remote Data Replication |
Remote data replication, data migration (options) |
| Other |
Thin Provisioning, Power Saver (included with hardware) SQL replication, Volume WORM (options) |
| | |
| PHYSICAL SPECIFICATIONS |
| Size of Cabinet chassis (HxWxD) |
|
| Size of Rack chassis (HxWxD) |
| º Disk Array Controller Unit |
86,5 x 480 x 540 mm |
| Extension module rack size (HxWxD) |
86,5 x 480 x 540 mm |
| Weight |
| º Disk Array Controller Unit |
31Kg |
| º Disk Enclosure Controller Unit |
29Kg |
| Height standard EIA |
| º Disk Array Controller Unit |
2U ou 2 EIA |
| º Disk Enclosure Controller Unit |
2U ou 2 EIA |
| | |
| POWER |
| Power consumption (basic chassis) |
3.5’’ : SAS 15k : 480 W max, 345W in idle mode; NL-SAS 7200rpm : 420W max, 285W in idle mode |
| Power consumption (add-on disk encl.) |
3.5’’ : SAS 15k : 315W max, 215W in idle mode; NL-SAS 7200RPM : 260W max, 155W in idle mode |
| Voltage |
2 prises AC100 à 240V; 50/60 Hz |
| | |
| ENVIRONMENTAL CONSTRAINTS |
| Operating constraints |
5-40°C, 10%-80% |
| | |
| SOFTWARE CERTIFICATION |
| Windows Server 2008 |
Yes including FCCP clusters |
| Windows Server 2003 |
Oui incluant MSCS clusters |
| Red Hat Enterprise Linux 5.0 |
Yes |
| Red Hat Enterprise Linux 6.0 |
Yes |
| Unix |
AIX 5.3, AIX 6.1, AIX 7.1 |
| Other OS |
VMware ESX4, ESX5, GCOS7 |
| | |
| REGULATORY & SAFETY |
| Regulatory compliance |
UL, CSA, CE, FCC |
| | |
| WARRANTY |
| Standard warranty |
3 Years Customer Replacable Units, D+1 |
| Warranty extension |
Bull Global Care : bronze, silver or gold |
| |