| GLOBAL CHARACTERISTICS |
| Rack chassis version |
2U base with disks + 2U disks drawers; 12x3.5’’ slots drawer or 24x2.5’’ slots drawer; maximum 144 disks |
| Total Storage Capacity |
Up to 104.4 TB SAS or 279.5 TB NL-SAS |
| Disk modules (hot swap) |
3 to 144 disks (12x3.5’’ or 24x2.5’’ per drawer) |
| RAID capability |
RAID0, 1, 5, 6, 10, 50 and Triple Mirror |
| Interface to host |
8 Gb/s Fibre Channel or 1 Gb/s iSCSI or 10Gb/s iSCSI or 6 Gb/s SAS |
| Max number of port to host |
8x FC, 4x iSCSCI 1Gb/s or 10Gb/s, or 4x FC + 4x iSCSI 1Gb/s, or 8x 6Gb/s SAS |
| Interface to disks |
2 SAS 6Gb/s links |
| Power Supply Redundancy |
Yes |
| Fan Redundancy |
Yes |
| | |
| CONTENT OF BASIC CHASSIS |
| RAID controller /SP |
Dual 8Gb/s FC, dual 1Gb/s or 10Gb/s iSCSI, dual combo FC+1Gb/s iSCSI, dual 6Gb/s SAS |
| Cache memory per RAID controller/SP |
4GB per controller, upgradable to 8GB (16GB total) |
| Cache memory configurability |
Yes |
| Hot-Plug Power Supply |
Yes |
| Battery Backup (BBU ou SPS) |
BBU for copy of cache in flash on the controller in case of power down |
| Host Management |
LAN TCP/IP, FC SES, snmp, email events |
| | |
| OPTIONS ON TOP OF BASIC CHASSIS |
| Hard Disk Drives 7.2Krpm |
2,5’’ : 3 x 1000 GB ; 3,5’’ : 3 x 1000 GB , 3x 2000GB, 3x 3000GB, 3x 4000GB |
| Hard Disk Drives 10Krpm |
2,5’’ : 3 x 300 GB , 3 x 450 GB, 3x 600GB, 3x 900GB |
| Hard Disk Drives 15 Krpm |
3,5’’ : 3 x 300 GB, 3 x 450 GB, 3x 600GB; 2,5’’ : 3x 300GB |
| Solid State Drives |
2,5’’ : 1x 100GB, 1x 400GB; 3,5’’ : 1x 100GB, 1x 400GB |
| | |
| STORAGE MANAGEMENT SOFTWARE |
| Storage Management |
StoreWay Optima Manager |
| Multi-path Management |
StoreWay Multipath for Windows and Linux StoreWay Multipath for VMware StoreWay Multipath for AIX
|
| LUN mapping/Multi-server storage access |
Yes |
| Performance Monitoring |
Performance Monitor, Performance Navigator, Performance Optimizer , Performance Monitor Suite, Performance Optimizer Suite(options) |
| Snap Shot |
Dynamic snap volume (included with Local Data Replication) |
| Local Data Replication |
Local data replication (option) |
| Remote Data Replication |
Remote data replication, Data Migration (options) |
| Other |
Thin Provisioning, Power Saver (included with hardware); SSD cache, Virtual Cache Partitioning, SQL replication, Volume WORM (options) |
| | |
| PHYSICAL SPECIFICATIONS |
| Size of Cabinet chassis (HxWxD) |
|
| Size of Rack chassis (HxWxD) |
| º Disk Array Controller Unit |
86,5 x 480 x 540 mm |
| Extension module rack size (HxWxD) |
86,5 x 480 x 540 mm |
| Weight |
| º Disk Array Controller Unit |
31Kg max |
| º Disk Enclosure Controller Unit |
29Kg max |
| Height standard EIA |
| º Disk Array Controller Unit |
2U ou 2 EIA |
| º Disk Enclosure Controller Unit |
2U ou 2 EIA |
| | |
| POWER |
| Power consumption (basic chassis) |
490 W max (320W in idle mode) |
| Power consumption (add-on disk encl.) |
310W max (160W in idle mode) |
| Voltage |
2 prises AC100 à 240V; 50/60 Hz |
| | |
| ENVIRONMENTAL CONSTRAINTS |
| Operating constraints |
5-40°C, 10%-80% |
| | |
| SOFTWARE CERTIFICATION |
| Windows Server 2012 |
Yes including WSFC clusters |
| Windows Server 2008 |
Yes including WSFC clusters |
| Windows Server 2003 |
Yes including MSCS clusters |
| Red Hat Enterprise Linux 5 |
RHEL 5.5, 5.6, 5.7 |
| Red Hat Enterprise Linux 6 |
RHEL6.1, 6.2, 6.3 |
| Unix |
AIX 5.3, AIX 6.1, AIX 7.1, HP-UX, Solaris |
| Other OS |
VMware ESX/ESXi 4.0, 4.1, ESXi 5.0, ESXi 5.1 |
| | |
| REGULATORY & SAFETY |
| Regulatory compliance |
UL, CSA, CE, FCC |
| | |
| WARRANTY |
| Standard warranty |
3 Years, Customer Replacable Units, D+1 |
| Warranty extension |
Bull Global Care : bronze, silver or gold |
| |