| PRODUCT |
| Model |
Bull Blade Chassis - Enterprise |
| | |
| Media Tray (on front) |
| DVD-ROM drive |
included |
| Universal Serial Bus |
yes 2xUSB 2.0 |
| Front system |
LED panel for Light Path Diagnostics |
| | |
| Module Bays (on rear) |
| Hot-swap power |
4x hot-swap 220-240 -volt power-module bays (on front) |
| hot-plug management |
2x hot-plug management module bays |
| hot-plug switch |
10xhot-swap I/O-module bays |
| hot-swap blower |
2x hot-swap blower bays |
| | |
| Blade Bays (on front) |
| Nb of hot-plug blade bays |
14x hot-plug blade bays |
| | |
| Redundant Cooling |
| Cooling Description |
2x redundant variable-speed hot-swap blowers |
| | |
| Power Modules |
| Standard |
2x 2980-watt or greater (200-240VAC) hot-swap power modules; both power modules provide redundancy to each other |
| Maximum |
x4 |
| | |
| Switch Modules |
| Standard |
for maximum flexibility, network module isn’t included |
| Maximum |
2x hot-plug Ethernet switch or pass-through modules and two hot-plug switch/pass-through modules of Ethernet or Fibre channel (depending on the chosen type of mezanine card). |
| | |
| Chassis Management Module |
| Description |
Redundant hot-plug management modules |
| System |
Management functions for the entire Bull Blade Chassis |
| Video Port |
Analog |
| Keyboard Port |
USB |
| Mouse Port |
USB |
| Remote Management Connection |
10/100 Mb Ethernet |
| | |
| Upgradeable Microcode |
| Management Module |
firmware |
| Ethernet Switch Module |
firmware |
| Blade Server Service Processor |
firmware |
| | |
| Security Features |
| Remote connection |
Login password |
| Remote Management Access |
Secure socket layer (SSL) security |
| | |
| Predictive Failure Analysis (PFA) Alerts |
| Blowers |
YES |
| Blade |
YES, features depend per blade |
| | |
| Size |
| Height |
400.1 mm (15.75 in. or 9 U) |
| Depth |
711.2mm (28") |
| Width |
482.6 mm (19 in.) |
| Weight |
158,8 kg fully configured with modules and blades. Empty chassis without modules or blade servers: Approximately 40,82 kg |
| | |
| Acoustical Noise Emissions |
| Without Acoustics |
| º Module Option |
7,5 bells |
| | |
| Environnement |
| Air temperatue |
| º Operating (system) |
10° to 35°C (50° to 95°F) |
| º Non-operating (system) |
–40° to +60°C (-40° to +140°F) |
| Humidity |
| º Operating (system) |
8% to 80% |
| º Non-operating (system) |
8% to 80% |
| | |
| Electrical input |
| (50-60Hz single phase) required Max |
240 volts AC |
| | |
| Heating Output |
| Minimum configuration |
1705 BTU/hour (0,5KVA) |
| Maximum configuration |
27280 BTU/hour (8.0KVA) |
| | |
| Safety Compliance |
| Safety |
Low Voltage Directive, 73/23/EEC, TUV/GS to EN60950 2nd Edition with Amendments, A1= A2 + A3 + A4 |
| Emissions |
EMC Directive 89/336/EEC, BSMI approval, FCC CFR 47 Part 2 abd 1, Verified Class A Limit |
| Environmental |
ROHS compliant |
| | |
| WARRANTY & SERVICES |
| Standard warranty |
3 years onsite |
| Warranty extension |
Optional Warranty extensions available, please contact local interface |
| Other services (installation …) |
installation, implementation, deployment, network and remote management |
| |