| SAN NETWORKING |
| Fibre Channel ports |
Switch mode (default): 12- and 24-port configurations (12-port increments through Port on Demand (PoD) licenses); universal (E, F, M, D, Ex) ports; Brocade Access Gateway default port mapping: 16 F_ports and 8 N_ports |
| Scalability |
Full fabric architecture with a maximum of 239 switches |
| Certified maximum |
6000 active nodes; 56 switches, 19 hops in FOS fabrics; 31 switches, 3 hops in M-EOS fabrics; Larger fabrics certified as required |
| Interoperability |
SAN fabrics running Fabric OS native and FOS open modes; SAN fabrics running McData Entreprise OS (M-EOS) native and M-EOS open modes. |
| Performance |
Auto-sensing of 2, 4, 8, and 16 Gb/s port speeds |
| Aggregate bandwidth |
384 Gb/s end-to-end full duplex |
| Fabric latency |
Latency for locally switched ports is 700 ns; Forward Error Correction (FEC) adds 400 ns between E_Ports (enabled by default) |
| Maximum frame size |
2112-byte payload |
| Classes of service |
Class 2, Class 3, Class F (inter-switch frames) |
| Port types |
D_Port (Diagnostic Port), E_Port, EX_Port, F-Port, M_Port (Mirror Port); self-discovery based on switch type (U_Port); optional port type control; Brocade Access Gateway mode: F_port and NPIV-enabled N_Port
|
| Data traffic types |
Fabric switches supporting unicast |
| Fibre Channel Media types |
Hot-pluggable, Industry-standard Small Form-factor Pluggable (SFP+), LC connector; Short-Wavelength (SWL); Long- Wavelength (LWL); Extended Long-Wavelength (ELWL); distance depends on fiber-optic cable and port speed. Supports SFP+ (8 and 16 Gb/s) optical transceivers |
| ISL Truncking |
Frame-based trunking with up to eight 16 Gbps ports per ISL trunk; up to 128 Gbps per ISL trunk. Exchange-based load balancing across ISLs with DPS included in Fabric OS. There is no limit to how many trunk groups can be configured in the switch. |
| Fabric services |
Advanced Performance Monitoring (including Top Talkers for E_Ports, F_Ports, and Fabric mode); Adaptive Networking (Ingress Rate Limiting, Traffic Isolation, QoS); Bottleneck Detection; Advanced Zoning (default zoning, port/WWN zoning, broadcast zoning); Dynamic Fabric Provisioning; Dynamic Path Selection; Extended Fabrics; Enhanced BB credit recovery; Fabric Watch; FDMI; Frame Redirection; Frame-based Trunking; FSPF; IPoFC; ISL Trunking; Management Server; NPIV; NTP v3; Port Fencing; Registered State Change Notification; Reliable Commit Service; Server Application Optimization; Simple Name Server; Note: Some fabric services do not apply or are not available in Access Gateway mode. |
| | |
| MANAGEMENT |
| Management software |
HTTP, SNMP v1/v3 (FE MIB, FC Management MIB), SSH; Auditing, Syslog; Brocade Advanced Web Tools, Advanced Performance Monitoring, Brocade Fabric Watch; Brocade Network Advisor SAN Enterprise or Brocade Network Advisor SAN Professional/Professional Plus; Command Line Interface ; SMI-S compliant; Administrative Domains; trial licenses for add-on capabilities |
| Management access |
10/100 Mbps Ethernet (RJ-45), in-band over Fibre Channel, serial port (RJ-45), and one USB port |
| Diagnostics |
D_Port offline diagnostics, including electrical / optical loopback, link traffic / latency / distance; POST and embedded online / offline diagnostics, including environmental monitoring, FCping and Pathinfo (FC traceroute), frame viewer, non-disruptive daemon restart port mirroring (SPAN port), optics health monitoring, power monitoring, RAStrace logging, and Rolling Reboot Detection |
| | |
| PHYSICAL SPECIFICATIONS |
| Enclosure |
Back-to-front airflow (port side exhaust); power from back, 1U |
| Size (HxWxD) |
4.3 cm (1.7 in) x 43.8 cm (17.23 in) x 44.3 cm (17.45 in) |
| Weight |
7.82 kg (17.25 lb) with one power supply, no transceivers; 9.16 kg (20.19 lb) with two power supplies, no transceivers |
| | |
| ENVIRONNEMENT |
| Temperature |
Operating: 0 °C to 40 °C; Non-operating: -25 °C to 70 °C |
| Humidity |
Operating: 10 % to 85 % non-condensing; Non-operating: 10 % to 90% non-condensing |
| Altitude |
Operating: up to 3000 m (9843 feet); Storage: up to 12 km (39,730 feet) |
| Shock |
Operating: 20 G, 6 ms half-sine; Non-operating: half-sine, 33 G 11 ms, 3/eg Axis |
| Vibration |
Operating: 0.5 g sine, 0.4 grms random, 5-500 Hz; Non-operating: 2.0 g sine, 1.1 grms random, 5-500 Hz |
| Heat Dissipation |
24 ports at 338 BTU/hr |
| | |
| POWER |
| AC input |
Nominal: 85 to 264 VAC 5A to 2.5A |
| Frequency |
47 to 63 Hz |
| Power Consumption |
80 watts with all 24 ports populated with optics; 60 watts for empty chassis, no optics |
| | |
| REGULATORY COMPLIANCE |
| Safety |
Bi-Nat UL/CSA 60950-1; EN60950-1; IEC60950-1; EN60825 |
| EMC |
FCC Part 15 Subpart B; ICES-003 Class A; EN55022 and EN55024; EN61000-3; EN61000-4 |
| | FC-AL-2; FC-GS-5; FC-IFR; FC-SW-4; FC-VI; FC-TAPE; FC-DA; FC-MI-2; FC-PI; FC-PI-2; FC-PI-4; FC-FS-2; FC-LS; FC-BB-3; FC-SB-3;RFC 2625 IP & ARP / FC; RFC 2837 MIB; MIB-FA; FCP-2; SMI-S 1.2 |
| | |
| WARRANTY |
| Standard warranty |
World Wide; 1 year Hardware support, 9x5 Next Business Day, onsite response |
| Warranty extension |
4 hour, 7x24 onsite response (depending on location) |
| |